1.
Heliyon ; 8(12): e12116, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36544820

RESUMO

The lateral flow immunoassay (LFIA) is a paper-based platform with extensive application in point-of-care (POC) testing and many fields. However, its clinical application is severely limited due to the lack of quantitative ability of standard LFIA tests; this augmentation provides the system with quantifying the signal from magenta-colored AuNPs. To address this issue, we proposed an ultra-compact optical system that allowed LFIAs to be performed more accurately and objectively. The experimental setup consisted of multiple optical accessories manufactured by 3D printing (STEP files were included). A high-resolution printer was used to print out a magenta card model for the LFIA, whose color code, ranging from 255, 255, 255 to 255, 0, 255 in the RGB (red, green, blue) format, represents different levels of magenta color intensity (from 0% to 100%) and thus the results of LFIA test strips. A mathematical model was built using a calibration curve to describe the relationship between magenta color value and reflectance spectrum. In addition, a spectrum module was integrated into the proposed system to identify and quantify LFIA results. This integration represents a pioneering step in developing portable detection techniques that facilitate quantifying LFIA results. Finally, we expect this ultra-compact optical spectroscopy system to have great potential for novel clinical applications.

2.
Med Sci Monit ; 28: e935812, 2022 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-35340017

RESUMO

BACKGROUND The COVID-19 pandemic has spread globally in a short period of time. It is known that antibody (nAb) level can effectively predict vaccine efficacy, which leads to the exploration of vaccine trials for efficacy assessment. Thus, the current study aimed to develop a platform to quantify nAb levels faster, at lower cost, and with better efficiency. MATERIAL AND METHODS A total of 69 sera samples were collected for the research, 28 of which were from unvaccinated participants. The other 27 samples and the remaining 14 samples were from the participants who had received the first and second dose, respectively, of AZ vaccine 1 month before. With cPass assays (Genscript cPass nAb ELISA assay) used as a criterion standard and lateral flow immunoassay kit (Healgen Scientific - LFIA test kit) coupled with a spectrometer (LFIA+S) for checking each specimen, we aimed to detect the presence of neutralizing antibodies in sera and to confirm the relationship between the inhibition rate from cPass assays and the nAb index from the LFIA+S. RESULTS Data analysis of the research were taken from the certified ELISA and LFIA+S, which indicated a high consistency (Pearson's r =0.864; ICC=0.90138) between the 2 methods. CONCLUSIONS The dataset demonstrated that LFIA+S was affordable, had a strong correlation with results of the cPass nAbs detection kit, and has potential clinical applications, with an exclusive feature that allows non-experts to use it with ease. It is believed that the proposed platform can be promoted in the near future.


Assuntos
COVID-19 , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Imunoensaio/métodos , Pandemias , SARS-CoV-2
3.
PLoS One ; 16(7): e0254486, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34283860

RESUMO

The coronavirus disease (COVID-19) is the global public health challenge currently persisting at a grand scale. A method that meets the rapid quantitative detection of antibodies to assess the body's immune response from natural COVID-19 illness or vaccines' effects is urgently needed. In the present study, an attempt was made to integrate a newly designed spectrometer to the COVID-19 test strip procedure; this augmentation provides the quantitative capacity to a lateral flow immunoassay (LFIA). Optical interpretation of results by quantitative α index, rather than visual qualification, can be done quickly, in 5-10 minutes. The developed product was compared with several other serological IgM/IgG antibody reagents on the market by recruiting 111 participants suspected of having COVID-19 infection from March to May 2020 in a hospital. Taking RT-PCR as the diagnostic gold standard, the quantitative spectral LIFA platform could correctly detect all 12 COVID-19 patients. Concerning RT-PCR negative patients, all three antibody testing methods found positive cases. The optical-based platform exhibited the ability of early detection of immunoglobulins of RT-PCR negative patients. There was an apparent trend that elevation of IgM levels in the acute phase of infection; then IgG levels rose later. It exhibited the risk of a false-negative diagnosis of RT-PCR in COVID-19 testing. The significant detection ability of this new optical-based platform demonstrated clinical potential.


Assuntos
COVID-19/imunologia , Imunoensaio/métodos , Isotipos de Imunoglobulinas/análise , Humanos , Pandemias , Reação em Cadeia da Polimerase Via Transcriptase Reversa
4.
Micromachines (Basel) ; 12(3)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803850

RESUMO

As coronavirus disease 2019 (COVID-19) continues to spread around the world, the establishment of decentralized severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) diagnostics and point-of-care testing is invaluable. While polymerase chain reaction (PCR) has been the gold standard for COVID-19 screening, serological assays detecting anti-SARS-CoV-2 antibodies in response to past and/or current infection remain vital tools. In particular, lateral flow immunoassay devices are easy to produce, scale, distribute, and use; however, they are unable to provide quantitative information. To enable quantitative analysis of lateral flow immunoassay device results, microgating technology was used to develop an innovative spectrochip that can be integrated into a portable, palm-sized device that was capable of capturing high-resolution reflectance spectrum data for quantitative immunoassay diagnostics. Using predefined spiked concentrations of recombinant anti-SARS-CoV-2 immunoglobulin G (IgG), this spectrochip-coupled immunoassay provided extraordinary sensitivity, with a detection limit as low as 186 pg/mL. Furthermore, this platform enabled the detection of anti-SARS-CoV-2 IgG in all PCR-confirmed patients as early as day 3 after symptom onset, including two patients whose spectrochip tests would be regarded as negative for COVID-19 using a direct visual read-out without spectral analysis. Therefore, the quantitative lateral flow immunoassay with an exceptionally low detection limit for SARS-CoV-2 is of value. An increase in the number of patients tested with this novel device may reveal its true clinical potential.

5.
Diagnostics (Basel) ; 11(1)2020 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-33375112

RESUMO

Paraquat is a highly toxic herbicide. Paraquat poisoning is often fatal and is an important public health threat in many places. The quick identification and timely initiation of treatment based on timely analysis of the paraquat concentration in urine/serum could improve the prognosis for patients. However, current paraquat concentration measurements are time-consuming and difficult to implement due to the expensive and bulky equipment required. To address these practical challenges, paper-based devices have emerged as alternative diagnostic tools for improving point-of-care testing. In this study, we demonstrate the successful use of a paper-based analytical device for the accurate detection of urine paraquat concentration. The developed paper-based analytical device employs colorimetric paraquat concentration measurements. The R2 value for the urine paraquat standard curve was 0.9989, with a dynamic range of 0-100 ppm. The limit of detection was 3.01 ppm. Two other optical-based approaches, Spectrochip and NanoDrop, were used for comparison. The results suggest that the developed paper-based analytical device is comparable to other colorimetric measurements, as determined by Bland-Altman analysis. The device was clinically validated using urine from six paraquat-poisoned patients. The results prove that the developed paper-based analytical device is accurate, easy-to-use, and efficient for urine paraquat concentration measurement, and may enable physicians to improve clinical management.

6.
Appl Opt ; 55(17): 4531-7, 2016 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-27409008

RESUMO

A two-dimensional thin film thickness model based on the geometry of a commercial coater which can calculate more effectively the profiles of linear variable filters (LVFs) has been developed. This is done by isolating the substrate plane as an independent coordinate (local coordinate), while the rotation and translation matrices are used to establish the coordinate transformation and combine the characteristic vector with the step function to build a borderline which can conclude whether the local mask will block the deposition or not. The height of the local mask has been increased up to 40 mm in the proposed model, and two-dimensional simulations are developed to obtain a thin film profile deposition on the substrate inside the evaporation chamber to achieve the specific request of producing a LVF zone width in a more economical way than previously reported [Opt. Express23, 5102 (2015)OPEXFF1094-408710.1364/OE.23.005102].

7.
Opt Express ; 23(4): 5102-16, 2015 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-25836544

RESUMO

This paper proposes an innovative method to overcome the low production rate of current linear variable filter (LVF) fabrication. During the fabrication process, a commercial coater is combined with a local mask on a substrate. The proposed analytical thin film thickness model, which is based on the geometry of the commercial coater, is developed to more effectively calculate the profiles of LVFs. Thickness tolerance, LVF zone width, thin film layer structure, transmission spectrum and the effects of variations in critical parameters of the coater are analyzed. Profile measurements demonstrate the efficacy of local mask theory in the prediction of evaporation profiles with a high degree of accuracy.

8.
Opt Express ; 15(17): 10498-503, 2007 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-19547403

RESUMO

The miniature spectrometer has many applications in integrated optics and photonics. The blazed grating with the Rowland circle structure has the advantage of self-focusing and is chosen as the major component in the spectrometer chip. In the simulations for the blaze angle design in the visible spectrum, we discover the phenomenon of the double reflection diffraction. Its cause and parameter space are discussed. The spectrometer utilizing the phenomenon has similar performance to the standard blazed grating and is easier to manufacture in microelectromechanical systems (MEMS) technology. The discovery will greatly ease the design of the spectrometer chip.

9.
Opt Express ; 14(7): 2611-7, 2006 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-19516391

RESUMO

An S-band gain-clamped erbium-doped fiber amplifier module, employing a fiber Bragg grating to serve as a reflected element for lasing a saturated tone injected into the module by forward optical feedback method, is proposed and investigated experimentally. Moreover, the performance and behavior of the gain and noise figure in the proposed gain-clamped S-band fiber amplifier have also been discussed in the effectively wavelength range of 1478 to 1520 nm.

10.
Opt Express ; 14(12): 5250-9, 2006 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-19516690

RESUMO

The construction by CMOS Cu-interconnect fabrication technology of an optical chip that performs the function of linear polarization is described. The chip consists of three rows of a one dimensional array of rods in a square lattice structure. The rods make use of the Cu-interconnects of a CMOS IC for this optical purpose. The whole structure embedded inside a slab waveguide. The optical properties of the device in the optical communication wavelength range (1.475 microm ~ 1.625 microm) are simulated using the finite-difference-time-domain (FDTD) approach. Under double-cascaded operation, a linear polarization ratio as high as 10(6) can be achieved. Our study shows that the CMOS IC technology can be used a tool for mass fabrication of passive integrated optical chips for optical communications.

SELEÇÃO DE REFERÊNCIAS